16“ center bracket to 24” center framing
I'm installing a tankless water heater (150lbs static load, 10" deep)
I only have one option for installation and it is a 2x3 framed wall with 24" centers.
The Top bracket is designed to mount on top of a horizontal crossmember with screws penetrating the cross member in four locations and the studs in two. The bottom bracket requires a cross member as well but it just bolts to the cross member.
My question is this. What is the best way to install this right (without rebuilding the wall). Double jack studs would work if the actual dimensions were 2x3, which they are not. Should I just add another stud inside and work off of that?
framing mounting tankless
add a comment |
I'm installing a tankless water heater (150lbs static load, 10" deep)
I only have one option for installation and it is a 2x3 framed wall with 24" centers.
The Top bracket is designed to mount on top of a horizontal crossmember with screws penetrating the cross member in four locations and the studs in two. The bottom bracket requires a cross member as well but it just bolts to the cross member.
My question is this. What is the best way to install this right (without rebuilding the wall). Double jack studs would work if the actual dimensions were 2x3, which they are not. Should I just add another stud inside and work off of that?
framing mounting tankless
Do you mean to add 5 2x3's? Or 2 perpendicular (hint hint) ... or are you saying you'll add ONE full length to get the 16"? Any of those should work as long as its static and all points are well secured.
– noybman
Dec 16 '18 at 15:47
add a comment |
I'm installing a tankless water heater (150lbs static load, 10" deep)
I only have one option for installation and it is a 2x3 framed wall with 24" centers.
The Top bracket is designed to mount on top of a horizontal crossmember with screws penetrating the cross member in four locations and the studs in two. The bottom bracket requires a cross member as well but it just bolts to the cross member.
My question is this. What is the best way to install this right (without rebuilding the wall). Double jack studs would work if the actual dimensions were 2x3, which they are not. Should I just add another stud inside and work off of that?
framing mounting tankless
I'm installing a tankless water heater (150lbs static load, 10" deep)
I only have one option for installation and it is a 2x3 framed wall with 24" centers.
The Top bracket is designed to mount on top of a horizontal crossmember with screws penetrating the cross member in four locations and the studs in two. The bottom bracket requires a cross member as well but it just bolts to the cross member.
My question is this. What is the best way to install this right (without rebuilding the wall). Double jack studs would work if the actual dimensions were 2x3, which they are not. Should I just add another stud inside and work off of that?
framing mounting tankless
framing mounting tankless
asked Dec 16 '18 at 15:40
mreff555mreff555
298111
298111
Do you mean to add 5 2x3's? Or 2 perpendicular (hint hint) ... or are you saying you'll add ONE full length to get the 16"? Any of those should work as long as its static and all points are well secured.
– noybman
Dec 16 '18 at 15:47
add a comment |
Do you mean to add 5 2x3's? Or 2 perpendicular (hint hint) ... or are you saying you'll add ONE full length to get the 16"? Any of those should work as long as its static and all points are well secured.
– noybman
Dec 16 '18 at 15:47
Do you mean to add 5 2x3's? Or 2 perpendicular (hint hint) ... or are you saying you'll add ONE full length to get the 16"? Any of those should work as long as its static and all points are well secured.
– noybman
Dec 16 '18 at 15:47
Do you mean to add 5 2x3's? Or 2 perpendicular (hint hint) ... or are you saying you'll add ONE full length to get the 16"? Any of those should work as long as its static and all points are well secured.
– noybman
Dec 16 '18 at 15:47
add a comment |
2 Answers
2
active
oldest
votes
I would fit two 2x6 (or larger) blocks crossways between your studs at the two mounting locations. Put three 3" construction (not black drywall) screws through the studs into each end of the blocks. Pilot through the studs to avoid splitting. You won't need to pilot into the end-grain of the blocks unless they're very hard wood.
___________________________________
___________________________________
| |* | |* <-- toenail screws or angle brackets
| | | |
| | | |
| | | |
| |______________________| |
| | | |*
| | 2x6 block | |* <-- three screws
| |______________________| |*
| | | |
| | | |
| | | |
This will easily carry your heater. The only weakness at this point is the connection of each stud to the top plate. you might add toenailed screws or angle brackets there.
You could also lay in two 2x6 studs, flatwise, tight to each 2x3 stud in the bay where you'll mount the heater. This would give more horizontal stiffness if you feel like your studs are too flexible. Run screws through the 2x3 studs every foot or so.
___________________________________
___________________________________
| | | | | |
| | | | | |
| | 2x6 | | 2x6 | |
| | | | | |
| | | | | |
add a comment |
The other answer given so far describes a solution where the tankless water heater is being installed in an area where the studs are open and not covered. There are instances where the studs are not open and may be covered with drywall (a.k.a. sheet rock). It this instance the installation of extra studs or cross blocking is not so easy and other methods are called for. I will describe two options:
- You can cover the entire wall area where the brackets will be attached with a piece of 3/4" plywood. This may actually need to extend beyond the end of the bracket if the existing studs in the wall are farther away from the bracket mounting points. Secure the plywood to the wall surface using screws through the plywood and into the existing studding structure. Then mount the bracketing to the plywood. With proper size pilot holes for the screws the plywood does a really good job of holding the screws.
- An alternative solution would be to mount two horizontal 2x4s or 2x6s flat on the wall centered vertically where the tankless heater brackets will be located. These cross members are attached with screws at each existing stud location. They may have to extend longer than the width of the bracketing if the next stud is further over from the mounting location. Once the cross members are secured the bracketing can be screwed into the cross members.
Note: Either of these schemes can also be used on a wall that has open studs. In fact applying one of these techniques could even be easier to install than extra studs and blocking between existing studding.
1
This is where I was hinting at, but wasnt sure what was being implied by adding another stud inside. Your approach is how I've seen it done typically, and if in a utility area (hot water tank) its not an eyesore
– noybman
Dec 16 '18 at 19:06
I should have clarified. Framing only. Someone had finished the other side of the wall (poorly), but I have no desire to finish the basement. I simply want a sturdy structure.
– mreff555
Dec 20 '18 at 0:40
add a comment |
Your Answer
StackExchange.ready(function() {
var channelOptions = {
tags: "".split(" "),
id: "73"
};
initTagRenderer("".split(" "), "".split(" "), channelOptions);
StackExchange.using("externalEditor", function() {
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled) {
StackExchange.using("snippets", function() {
createEditor();
});
}
else {
createEditor();
}
});
function createEditor() {
StackExchange.prepareEditor({
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader: {
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
},
noCode: true, onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
});
}
});
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f152798%2f16-center-bracket-to-24-center-framing%23new-answer', 'question_page');
}
);
Post as a guest
Required, but never shown
2 Answers
2
active
oldest
votes
2 Answers
2
active
oldest
votes
active
oldest
votes
active
oldest
votes
I would fit two 2x6 (or larger) blocks crossways between your studs at the two mounting locations. Put three 3" construction (not black drywall) screws through the studs into each end of the blocks. Pilot through the studs to avoid splitting. You won't need to pilot into the end-grain of the blocks unless they're very hard wood.
___________________________________
___________________________________
| |* | |* <-- toenail screws or angle brackets
| | | |
| | | |
| | | |
| |______________________| |
| | | |*
| | 2x6 block | |* <-- three screws
| |______________________| |*
| | | |
| | | |
| | | |
This will easily carry your heater. The only weakness at this point is the connection of each stud to the top plate. you might add toenailed screws or angle brackets there.
You could also lay in two 2x6 studs, flatwise, tight to each 2x3 stud in the bay where you'll mount the heater. This would give more horizontal stiffness if you feel like your studs are too flexible. Run screws through the 2x3 studs every foot or so.
___________________________________
___________________________________
| | | | | |
| | | | | |
| | 2x6 | | 2x6 | |
| | | | | |
| | | | | |
add a comment |
I would fit two 2x6 (or larger) blocks crossways between your studs at the two mounting locations. Put three 3" construction (not black drywall) screws through the studs into each end of the blocks. Pilot through the studs to avoid splitting. You won't need to pilot into the end-grain of the blocks unless they're very hard wood.
___________________________________
___________________________________
| |* | |* <-- toenail screws or angle brackets
| | | |
| | | |
| | | |
| |______________________| |
| | | |*
| | 2x6 block | |* <-- three screws
| |______________________| |*
| | | |
| | | |
| | | |
This will easily carry your heater. The only weakness at this point is the connection of each stud to the top plate. you might add toenailed screws or angle brackets there.
You could also lay in two 2x6 studs, flatwise, tight to each 2x3 stud in the bay where you'll mount the heater. This would give more horizontal stiffness if you feel like your studs are too flexible. Run screws through the 2x3 studs every foot or so.
___________________________________
___________________________________
| | | | | |
| | | | | |
| | 2x6 | | 2x6 | |
| | | | | |
| | | | | |
add a comment |
I would fit two 2x6 (or larger) blocks crossways between your studs at the two mounting locations. Put three 3" construction (not black drywall) screws through the studs into each end of the blocks. Pilot through the studs to avoid splitting. You won't need to pilot into the end-grain of the blocks unless they're very hard wood.
___________________________________
___________________________________
| |* | |* <-- toenail screws or angle brackets
| | | |
| | | |
| | | |
| |______________________| |
| | | |*
| | 2x6 block | |* <-- three screws
| |______________________| |*
| | | |
| | | |
| | | |
This will easily carry your heater. The only weakness at this point is the connection of each stud to the top plate. you might add toenailed screws or angle brackets there.
You could also lay in two 2x6 studs, flatwise, tight to each 2x3 stud in the bay where you'll mount the heater. This would give more horizontal stiffness if you feel like your studs are too flexible. Run screws through the 2x3 studs every foot or so.
___________________________________
___________________________________
| | | | | |
| | | | | |
| | 2x6 | | 2x6 | |
| | | | | |
| | | | | |
I would fit two 2x6 (or larger) blocks crossways between your studs at the two mounting locations. Put three 3" construction (not black drywall) screws through the studs into each end of the blocks. Pilot through the studs to avoid splitting. You won't need to pilot into the end-grain of the blocks unless they're very hard wood.
___________________________________
___________________________________
| |* | |* <-- toenail screws or angle brackets
| | | |
| | | |
| | | |
| |______________________| |
| | | |*
| | 2x6 block | |* <-- three screws
| |______________________| |*
| | | |
| | | |
| | | |
This will easily carry your heater. The only weakness at this point is the connection of each stud to the top plate. you might add toenailed screws or angle brackets there.
You could also lay in two 2x6 studs, flatwise, tight to each 2x3 stud in the bay where you'll mount the heater. This would give more horizontal stiffness if you feel like your studs are too flexible. Run screws through the 2x3 studs every foot or so.
___________________________________
___________________________________
| | | | | |
| | | | | |
| | 2x6 | | 2x6 | |
| | | | | |
| | | | | |
edited Dec 16 '18 at 16:46
answered Dec 16 '18 at 16:21
isherwoodisherwood
45.1k453115
45.1k453115
add a comment |
add a comment |
The other answer given so far describes a solution where the tankless water heater is being installed in an area where the studs are open and not covered. There are instances where the studs are not open and may be covered with drywall (a.k.a. sheet rock). It this instance the installation of extra studs or cross blocking is not so easy and other methods are called for. I will describe two options:
- You can cover the entire wall area where the brackets will be attached with a piece of 3/4" plywood. This may actually need to extend beyond the end of the bracket if the existing studs in the wall are farther away from the bracket mounting points. Secure the plywood to the wall surface using screws through the plywood and into the existing studding structure. Then mount the bracketing to the plywood. With proper size pilot holes for the screws the plywood does a really good job of holding the screws.
- An alternative solution would be to mount two horizontal 2x4s or 2x6s flat on the wall centered vertically where the tankless heater brackets will be located. These cross members are attached with screws at each existing stud location. They may have to extend longer than the width of the bracketing if the next stud is further over from the mounting location. Once the cross members are secured the bracketing can be screwed into the cross members.
Note: Either of these schemes can also be used on a wall that has open studs. In fact applying one of these techniques could even be easier to install than extra studs and blocking between existing studding.
1
This is where I was hinting at, but wasnt sure what was being implied by adding another stud inside. Your approach is how I've seen it done typically, and if in a utility area (hot water tank) its not an eyesore
– noybman
Dec 16 '18 at 19:06
I should have clarified. Framing only. Someone had finished the other side of the wall (poorly), but I have no desire to finish the basement. I simply want a sturdy structure.
– mreff555
Dec 20 '18 at 0:40
add a comment |
The other answer given so far describes a solution where the tankless water heater is being installed in an area where the studs are open and not covered. There are instances where the studs are not open and may be covered with drywall (a.k.a. sheet rock). It this instance the installation of extra studs or cross blocking is not so easy and other methods are called for. I will describe two options:
- You can cover the entire wall area where the brackets will be attached with a piece of 3/4" plywood. This may actually need to extend beyond the end of the bracket if the existing studs in the wall are farther away from the bracket mounting points. Secure the plywood to the wall surface using screws through the plywood and into the existing studding structure. Then mount the bracketing to the plywood. With proper size pilot holes for the screws the plywood does a really good job of holding the screws.
- An alternative solution would be to mount two horizontal 2x4s or 2x6s flat on the wall centered vertically where the tankless heater brackets will be located. These cross members are attached with screws at each existing stud location. They may have to extend longer than the width of the bracketing if the next stud is further over from the mounting location. Once the cross members are secured the bracketing can be screwed into the cross members.
Note: Either of these schemes can also be used on a wall that has open studs. In fact applying one of these techniques could even be easier to install than extra studs and blocking between existing studding.
1
This is where I was hinting at, but wasnt sure what was being implied by adding another stud inside. Your approach is how I've seen it done typically, and if in a utility area (hot water tank) its not an eyesore
– noybman
Dec 16 '18 at 19:06
I should have clarified. Framing only. Someone had finished the other side of the wall (poorly), but I have no desire to finish the basement. I simply want a sturdy structure.
– mreff555
Dec 20 '18 at 0:40
add a comment |
The other answer given so far describes a solution where the tankless water heater is being installed in an area where the studs are open and not covered. There are instances where the studs are not open and may be covered with drywall (a.k.a. sheet rock). It this instance the installation of extra studs or cross blocking is not so easy and other methods are called for. I will describe two options:
- You can cover the entire wall area where the brackets will be attached with a piece of 3/4" plywood. This may actually need to extend beyond the end of the bracket if the existing studs in the wall are farther away from the bracket mounting points. Secure the plywood to the wall surface using screws through the plywood and into the existing studding structure. Then mount the bracketing to the plywood. With proper size pilot holes for the screws the plywood does a really good job of holding the screws.
- An alternative solution would be to mount two horizontal 2x4s or 2x6s flat on the wall centered vertically where the tankless heater brackets will be located. These cross members are attached with screws at each existing stud location. They may have to extend longer than the width of the bracketing if the next stud is further over from the mounting location. Once the cross members are secured the bracketing can be screwed into the cross members.
Note: Either of these schemes can also be used on a wall that has open studs. In fact applying one of these techniques could even be easier to install than extra studs and blocking between existing studding.
The other answer given so far describes a solution where the tankless water heater is being installed in an area where the studs are open and not covered. There are instances where the studs are not open and may be covered with drywall (a.k.a. sheet rock). It this instance the installation of extra studs or cross blocking is not so easy and other methods are called for. I will describe two options:
- You can cover the entire wall area where the brackets will be attached with a piece of 3/4" plywood. This may actually need to extend beyond the end of the bracket if the existing studs in the wall are farther away from the bracket mounting points. Secure the plywood to the wall surface using screws through the plywood and into the existing studding structure. Then mount the bracketing to the plywood. With proper size pilot holes for the screws the plywood does a really good job of holding the screws.
- An alternative solution would be to mount two horizontal 2x4s or 2x6s flat on the wall centered vertically where the tankless heater brackets will be located. These cross members are attached with screws at each existing stud location. They may have to extend longer than the width of the bracketing if the next stud is further over from the mounting location. Once the cross members are secured the bracketing can be screwed into the cross members.
Note: Either of these schemes can also be used on a wall that has open studs. In fact applying one of these techniques could even be easier to install than extra studs and blocking between existing studding.
answered Dec 16 '18 at 17:12
Michael Karas♦Michael Karas
43.6k43482
43.6k43482
1
This is where I was hinting at, but wasnt sure what was being implied by adding another stud inside. Your approach is how I've seen it done typically, and if in a utility area (hot water tank) its not an eyesore
– noybman
Dec 16 '18 at 19:06
I should have clarified. Framing only. Someone had finished the other side of the wall (poorly), but I have no desire to finish the basement. I simply want a sturdy structure.
– mreff555
Dec 20 '18 at 0:40
add a comment |
1
This is where I was hinting at, but wasnt sure what was being implied by adding another stud inside. Your approach is how I've seen it done typically, and if in a utility area (hot water tank) its not an eyesore
– noybman
Dec 16 '18 at 19:06
I should have clarified. Framing only. Someone had finished the other side of the wall (poorly), but I have no desire to finish the basement. I simply want a sturdy structure.
– mreff555
Dec 20 '18 at 0:40
1
1
This is where I was hinting at, but wasnt sure what was being implied by adding another stud inside. Your approach is how I've seen it done typically, and if in a utility area (hot water tank) its not an eyesore
– noybman
Dec 16 '18 at 19:06
This is where I was hinting at, but wasnt sure what was being implied by adding another stud inside. Your approach is how I've seen it done typically, and if in a utility area (hot water tank) its not an eyesore
– noybman
Dec 16 '18 at 19:06
I should have clarified. Framing only. Someone had finished the other side of the wall (poorly), but I have no desire to finish the basement. I simply want a sturdy structure.
– mreff555
Dec 20 '18 at 0:40
I should have clarified. Framing only. Someone had finished the other side of the wall (poorly), but I have no desire to finish the basement. I simply want a sturdy structure.
– mreff555
Dec 20 '18 at 0:40
add a comment |
Thanks for contributing an answer to Home Improvement Stack Exchange!
- Please be sure to answer the question. Provide details and share your research!
But avoid …
- Asking for help, clarification, or responding to other answers.
- Making statements based on opinion; back them up with references or personal experience.
To learn more, see our tips on writing great answers.
Some of your past answers have not been well-received, and you're in danger of being blocked from answering.
Please pay close attention to the following guidance:
- Please be sure to answer the question. Provide details and share your research!
But avoid …
- Asking for help, clarification, or responding to other answers.
- Making statements based on opinion; back them up with references or personal experience.
To learn more, see our tips on writing great answers.
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f152798%2f16-center-bracket-to-24-center-framing%23new-answer', 'question_page');
}
);
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Do you mean to add 5 2x3's? Or 2 perpendicular (hint hint) ... or are you saying you'll add ONE full length to get the 16"? Any of those should work as long as its static and all points are well secured.
– noybman
Dec 16 '18 at 15:47